MicroFUSION SEMI
Available in single phase with Copy Exact longevity. An ultra-compact, high-performance, microprocessor-based power controller specifically designed for the precise control requirements of the semiconductor industry.
EtherCAT
A high-speed, real-time Ethernet protocol designed for motion control and industrial automation.
100kA SCCR
Indicates the device can safely withstand up to 100,000 amps of short-circuit current.
CE
Indicates the product complies with European Union safety, health, and environmental requirements.
FCC
Confirms the product meets electromagnetic interference standards in the United States.
Product Information
MicroFUSION SEMI is an ultra-precise, single phase power controller featuring Copy Exact longevity and available in current ratings from 8 – 50 Amps AC.
Resistive or transformer-connected loads can be controlled with Phase Angle or HiPER mode. Output is controlled linearly and can be set to the average or RMS value of the voltage, current, and power.
MicroFUSION SEMI controllers offer the following features:
- Copy Exact longevity
- Auto-ranging voltage circuitry to enable main supply voltage (45-65 Hz)
- 24-600 VAC for UL/cUL
- 24-690 VAC for CE
- Robust design for continuous full-frame current operation without derating, up to 122°F [50°C], 6000 ft [1829 m] altitude
- 24 Vdc power source to supply control electronics and maintain critical communications
- Control setpoints through standard analog or optional digital fieldbus interfaces
- Status LEDs and an LED bar graph to quickly monitor operating status
- Plug-n-play USB interface and free Control Panel software
Dimensions shown in inches (mm)

DIN Mount

Panel Mount

Panel Mount with Fan
Specifications
| Phase | Single |
| Firing Mode |
Phase Angle HiPER Mode |
| Output | AC |
| Amp Sizes | 8A, 16A, 32A, 40A, 50A |
| Voltage |
24-690 VAC (CE) 24-600 VAC (UL) 45-65 Hz |
| Control | Analog or Digital |
| Feedback Type |
Voltage Current Power External *More options available upon factory consultation |
| Retransmit |
Load Voltage Load Current Load Power Load Resistance |
| Command Signal |
Standard: 0-5 VDC, 4-20 mA Field Scalable: 0-10 VDC, 0-20 mA, or Potentiometer |
| Limits |
Voltage Current Power |
| Alarms |
Overtemp Shorted SCR Communications Loss Current Limit Open Load Overcurrent Trip Partial Load Fault Power Limit Voltage Limit Phase Loss |
| Additional Features |
Adjustable soft start Missing cycle detection Trans-Guard Sync-Guard |
| Mean Time Between Failures (MTBF) | >50,000 hours |
| Line Voltage (Auto Ranging) |
UL/cUL: 24 – 600 Vac (Nominal) (+10% / -15%) CE: 24 – 690 Vac (Nominal) (+10% / -15%) (Contact CCI for other options) |
| Line Frequency (Auto Ranging) | 45 – 65 Hz |
| Frame Current Ratings (Amps) | Continuous RMS (AC): 8A, 16A, 32A, 40A, 50A |
| Current Rating – Peak Surge | 20x frame rating for 10 ms |
| Minimum Hold/Latch Current | 500 mA up to 50 A |
| Max Leakage Current | 10.6 mA @ 600 Vac 50/60 Hz |
| SCR Rating (PIV) | 1600 V peak forward & reverse |
| Fusing | Optional external Class T, branch-rated, touch-safe fusing |
| Thermal | Integrated heat sink thermal sensor |
| Current Limit | 20 – 105% of continuous rating of Frame Amp Rating |
| Current Trip | 50 – 450% of continuous rating |
| Power Dissipation | 1.3 W per amp of load current per phase |
|
Control Power / Operates Internal Control Electronics |
24 Vdc (+10 / -15%) |
| Surrounding Air Operating Temp | 32 to 122°F [0 to 50°C] |
| Humidity | 20% to 90% RH Non-Condensing |
| Rated Operating Altitude | Up to 6000 ft [1829 m] at full rated current |
| Contaminates |
RoHS Compliant Pollution Degree 2 (only non-conductive pollution occurs) |
| Storage Temperature | -4 to 176°F [-20 to 80°C] |
| Setpoint Resolution | 10k or 64k |
|
Internal Control Loop Resolution |
64k |
| Output Resolution | 60k @ 50 Hz, 50k @ 60 Hz |
| Response Time | Adjustable from 50 ms to 2 s |
| Voltage | 0.5% of frame rating |
| Current | 0.5% of frame rating |
| Power | 1.0% of frame rating |
| Output Linearity | 1.0% from (5 – 100%) output range |
| Accuracy | +10% to -15% line voltage change will result in a max output change of 0.05% from (5 – 100%) output range |
| Temperature Drift |
Output shall not change greater than 0.2% per degree C max over the operating temperature range from (5 – 100%) output range |
Downloads
| Software and Fieldbus Files – EtherNET/IP, PROFINET, Modbus TCP, EtherCAT | |
|---|---|
| Control Panel Software | Download |
| MicroFUSION EtherNet/IP EDS | Download |
| MicroFUSION PROFINET GSDML | Download |